Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 33 Next »

The Genovation MiniTerm 905 is a fully programmable LCD mini-terminal. The Mini Data Terminal supports simple and complex re-programmable key macros and system configurations. It includes detachable serial (RS232) and USB cables for easy setup and flexibility. The 905 has multiple card/tag reader options for fast and easy data transactions. The LCD can also be used as a customer display (pole display).

Genovation's MiniTerms are ideal whenever you need to add a user interface to a machine, device or process. The possibilities are endless -- MiniTerms are right at home whether connected to PCs, printers, automation or industrial control PLC systems, cash registers or other POS terminals, electronic musical instruments, high-speed video cameras, security systems, CNC mill control and industrial pendants, access control systems and digital signage -- just to name a few. Genovation™

 

 



Installation & Setup

Drivers should be installed on the machine using the device.

Step 1: Plug the USB into the computer.

Step 2: Establish Serving Line configurations

  • Login to Newton. 
  • Locate and click on the Administration and Maintenance tab.
  • Locate the Serving Line option in the Point-of-Sale Setup ribbon.
  • Select either Serving Lines or Serving Line Configs depending on if your District uses line or a particular template. If you are unsure, check with your point of contact in the District.

Step 3: Configure the Device in Newton

Step 3 includes instructions for both Serving Line and Serving Line Configs. Choose the correct section your District utilizes for setup.


  •  Serving Line - Click on the Serving Line option.
    • In the Serving-Line Maintenance window, select a cafeteria line by clicking on a row or using the drop-down arrow and click the Edit button. If you use the drop-down arrow, be sure to select the proper serving line to install the device.

    • Click on the Override Settings tab.
    • Scroll down and locate the Devices section in the parameters.
    • Once you have located the Devices section click on Customer Input Device #1, then the ellipsis  button.

    • Use the drop-down arrow to locate and select Genovation 900 series (HID) Series.

    • Establish line settings..
      • Device Index - The device index typically remains at 0.

 

    • Click Ok when you have completed adjusting the settings.

 

    • Click Ok again to exit out of the Edit Serving Line window.

 

    • Click Close in the Serving-Line Maintenance window.

 

  • Serving Line Configs - Click on the Serving Line Configs option.
    • In the Serving-Line-Configuration Maintenance window, click the Edit button.

    • Scroll down and locate the Devices section in the parameters.
    • Once you have located the Devices section click on Customer Input Device #1, then the ellipsis  button.

    • Use the drop-down arrow to locate and select Genovation 900 series (HID).

    • Establish line settings..
      • Device Index - The device index typically remains at 0.

 

    • Click Ok when you have completed adjusting the settings.

    • Click Ok again to exit out of the Edit Serving Line window.

 

    • Click Close in the Serving-Line Maintenance window.

Step 4: Test the Pinpad device.

Test the Pinpad device by starting a new meal. Ensure Newton is recognizing meals served in the system.

 



Usage

 

 

 

 

 

  • No labels