Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
 


Page Tree Search
rootPageNewton Home


Section Column
width45%
Overview

The Hyperion™ 1300g linear-imaging barcode scanner is ideal for scan-intensive and light industrial applications. It features an ideal balance of performance, ergonomics and best-in-class durability (as in tough-enough-to-hammer-nails durable). For years of hassle-free, getting-the-job-done performance, the Hyperion 1300g scanner is the one.

The 1300g scanner is fast and intuitive to use. Even better, it eliminates the need to buy specialty scanners. That’s because the 1300g scanner lets you read 13 mil barcodes out to 45.7 cm (18 in) and high-density barcodes as small as 3 mil.

And with no moving parts to wear out, the Hyperion 1300g scanner is one of the toughest general duty scanners on the market – so tough, in fact, you can hammer nails with it! Honeywell ™

Column
width5%

 

Column
width50%
Image Removed 


Table of Contents

Image Added




Installation & Setup

  • If you have any issues with the barcode, please refer to the User's Guide.
Note
titleNotes
  • Drivers should be installed on the machine using the device.
note
  • If you have other scanning devices connected, unplug them all. Be sure to note which USB ports other scanning devices are connected as they have already been established in Serving Line setup.
Note

Download and Install the Driver

Info

Administrator rights are required to install the device driver. If you do not have administrative rights to the computer(s) you are installing the device, contact Central Office support or your IT department.

  1. Access the Honeywell website
.
  • Select the Handheld Barcode Scanner from the navigation pane.
  • Select the Hyperion 1300g scanner from the list.
  • Click on the Software tab for the Hyperion 1300g scanner.
  • Click on the Honeywell Scanning and Mobility (HSM) USB Serial Driver under Drivers.
  • Locate the downloaded .zip file on your computer or local drive and double-click the file to open.
    Image Removed

  • Double-click the setup.bat file to begin the installation process.
    Image Removed 
  • Connect the Scanner

  • AnchorStep 3Step 3Locate the Correct Port Number
    1. for the Hyperion 1300g Light Industrial Scanner.
    2. Scroll to the bottom of the screen and select Downloads.
      Image Added
    3. Click the link (https://hsmftp.honeywell.com/) to access the Technical Support Downloads Portal. If you do not already have a Honeywell account, you will need to create one.


    4. Expand
      titleHoneywell Download Manager Installation Instructions
      1. Double-click the .msi file in your Downloads folder to start the installation process.
      2. Click Next to begin the download process.
        Image Added
      3. Read and accept the terms in the License Agreement. Then, click Next.
        Image Added
      4. The installer will automatically select a destination folder. Click Next.
        Image Added
      5. Click Install to begin the installation process. Administrative rights to the computer are necessary to install the driver. You may need to contact your IT department to install the driver or allow you administrative rights to the computer.

        Image Added

      6. If prompted, click Yes to allow the application to make changes to your computer.
      7. Click Finish.
        Image Added

        Download and install the Honeywell Download Manager
        Note: Clicking this link will automatically download the Honeywell Download Manager to your computer.



    5. From the Hyperion website, expand Software > Barcode ScannersSoftware > DriversHoneywell Scanning (HSM) USB Serial Driver > Current >HSM USB Serial Driver r1.19_Legacy Metrologic_uni-directional-WHQL-03-08-2013.zip. Then, click Download.
    6. Once you have the driver, make sure the scanner is not connected to the PC and run the setup.
      Image Added
      Image Added

    Connect the Scanner

    1. Plug the scanner into your computer, then scan the following barcodes.
      1. Scanning this barcode will Change the USB to Serial Emulation.
        Image Added
      2. Scanning this barcode will enable illumination mode on the scanner.
        Image Added
      3. Scanning this barcode will enable Standard Presentation mode (Trigger Mode 3).
        Image Added
    2. Determine which port the scanner is using.
        1. Click on the Start button from your computer.
        2. Locate and click on the Control Panel in the menu.

    Image Removed
  • Locate the Hardware settings and click on the title.
    Image Removed
        1. In the Hardware and Sound window, locate Device and Printers and click on Device Manager.
          Image Modified
        2. In the Device Manager window, locate Ports (COM & LPT). Click on the right-facing arrow to expand Ports and view port devices.
          Image Modified
        3. Locate the device named Honeywell Unidirectional Device (COM#) and double click.
          Image Modified
      1. Next, click on the Port Settings tab. You will need to make notes of the following information in order to proceed.
        1. COM# (In parenthesis at the top of the window)
        2. Bits per second
        3. Data Bits
        4. Parity
        5. Stop Bits
          Image Modified
    1. Login to Newton
      1. Login to Newton. 
      2. Locate and click on the 
    Administration
      1. Admin and Maintenance tab.
      2. Locate the Serving Line option in the Point-of-Sale Setup ribbon.
      3. Select either Serving Lines or Serving Line Configs depending on if your District uses line or a particular template. If you are unsure, check with your point of contact in the District.
        Image Modified
    1. Establish Serving Line configurations

      Note

      Step 5 includes instructions for both Serving Line and Serving Line Configs. Choose the correct section your District utilizes for setup.

      1. In the Serving-Line Maintenance window, select a cafeteria by clicking on a row or using the drop-down arrow and click the Edit button. If you use the drop-down arrow, be sure to select the proper serving line to install the device.
    Image Removed
      1. Image Added
      2. Click on the Override Settings tab.
      3. Scroll down and locate the Devices section in the parameters.
      4. Once you have located the Devices section click on Customer Input Device #1, then the ellipsis button.

    InfoIf Image Removed
      1.  If you were utilizing another input device and plan on the continued use of the other device, select Customer Input Device #2.

      1. Image Added

      2. Use the drop-down arrow to locate and select the Metrologic Barcode Scanner (Unidirectional Serial).
        Image Modified
      3. Ensure the settings match the information noted
    in Step 3
      1. in step 2b.
        1. Baud Rate
    =
        1. (Bits per second) - Click the cell and change it to match the device settings.
        2. Data Bits - Click the cell and change it to match the device settings.
        3. Parity - Click the cell and use the dropdown menu to match the device settings.
        4. Port Name - Click the cell and change it to match the device settings.
        5. Stop Bits - Click the cell and use the dropdown menu to match the device settings.
        6. Click Ok when you have completed adjusting the settings.
          Image Modified
      1. Click Ok again to exit out of the Edit Serving Line window.
      2. Click Close in the Serving-Line Maintenance window.

    Test the Scanner

    Test the scanner by starting a new meal, starting a serving line configured to the template, or modified for the scanner. Scan barcodes of a few students to ensure Newton is recognizing them in the system.

    Return to Top



    Usage

    1. Login to Newton (Back Office) from the main machine and start an operating day by clicking the Start Operating Day link on the checklist or Start New Day from the ribbon.
       Image Modified
    2. Start a meal (either breakfast or lunch) by clicking Start Meal (Lunch) or Start Meal (Breakfast) link on the checklist or use the Meal Control Panel in the ribbon to start a meal.
      Image Modified
    3. Ensure the date is correct on the Meal Calendar screen and click Ok.
      Image Modified
    4. On the POS serving line with the scanner, double click on the Newton POS icon to open up to the login screen.
      Image Modified

    Note

    1. Note: If you will be enrolling students on the main machine, locate the Meal Control Panel and click on Main Machine to run Newton POS.

      Image Modified

    2. Login to Newton POS by entering the username and password given to you by the system administrator, then click Ok.
      Image Modified
    3. In the Customer Input Device window, scan the student's barcode identification card.

    info
      1. In the bottom left-hand corner, notice which device is set for the serving line.
      2. In the bottom right-hand corner, the status of the device is shown. If it working properly, you should see Running. If the device is not functioning properly, you will see Error. Click on Error to review the message.

        Image Modified

    1. The student should appear in the Name window. Proceed with normal serving line processes.
      Image Modified

    Return to Top


    After you have finished with line servings, click the Quit Serving Line button to exit Newton POS.
    Image Modified

    Then, click the Exit Point-Of-Sale button.
    Image Modified

    Be sure to return to the main machine and stop the meal and post transactions for the day.

    Return to Top