Fujitsu provides a highly reliable biometric authentication system based on palm vein pattern recognition technology. PalmSecure™ features industry-leading authentication accuracy with extremely low false rates, and non-intrusive and contactless reader device provides ease of use with virtually no physiological restriction for all users. The Fujitsu PalmSecure sensor uses near-infrared light to capture a person's palm vein pattern, generating a unique biometric template that is matched against pre-registered user palm vein patterns. The palm vein device can only recognize the pattern if the blood is actively flowing within the individual's veins, which means that forgery is virtually impossible. Fujitsu™

For more information contact MCS Software - Sales.

Info

In order to enroll students using the palm scanner, please refer to the Palm Scanning Enrollment section of this page. There is also an additional  Palm Scanner Enrollment Video to enhance the written documentation.

 

 

Column
width5%

 

Column
width55%

 

...

Section
Column
width47%

 Features

  • Advanced biometric authentication algorithm delivers ultra-low FAR (false accept rate) and FRR (false reject rate) 
  • Contactless palm vein authentication is hygienic and noninvasive - No Residual Trace Technology 
  • Encrypted repository for template storage & enterprise level event logging capability
  • PalmSecure Authentication recognized by leading International Security Bodies, including International Common Criteria and CNIL Speed and Extensibility
  • Quick-start deployment across the enterprise raises security and adds value
  • SDK (Software Development Kit) for organizations deploying PalmSecure technology
  • Fast and easy registration with virtually no enrollment error
  • Biometric integration for third party Single Sign-On (SSO) solutions with PalmSecure LOGONDIRECTOR
Info

For those concerned with latex allergies, the Fujitsu Palm Scanner contains no latex products in the hand guide. The material is Polycarbonate/Acrylonitrile Butadiene Styrene (PC/ABS), a commonly used plastic.

Column
width6%

 

Column
width47%

 Technical Specs

Supply voltage (from USB power)4.4 to 5.4V (Input current: up to 500mA)
ReliabilityMTBF (mean time between failure):830,000 hours for sensor only. 250,000 hours for controller only
FAR (false accept rate)0.00008%
Sensor surface materialGlass
Palm Capture Distance2 inches from the surface of the sensor (+/- .5 inch)
Outer dimensions (sensor only)1.37(W) x 1.37(D) x 1.06(H) inches
Supported OSClient: Windows® 7, XP Pro, Vista, Redhat Linux Ver. 5
Server: Windows Server 2003 and 2008, Redhat Linux Ver. 5
Power consumption2.5W or less
Authentication response timeLess than 1 second
FRR (false reject rate)0.01%
Acoustic NoiseNone
Operating Temperature0°C to 60°C
Hand Guide MaterialPolycarbonate/Acrylonitrile Butadiene Styrene (PC/ABS)

...

 

 

...

Anchor
Installation Setup
Installation Setup
Installation & Setup

...

  • Establish line setting by using the drop-down arrows.
    • Auto Identify after Enrolling - Allows the line operator to continue with serving a meal as soon as a student's identification has been successfully established.
    • Device Index - The device index typically remains at 0.
    • FRR Level - False Rejection Rate Level establishes sensitivity when completing scanning.
    • Hand Guide Type - By default, the guide type is set for the Big Hand Guide. If you are using the smaller hand guide or have younger students, the type should be changed to ChildHandGuide.
    • Prompt to Start Enrollment - Allows the line operator to choose when to begin the enrollment process.
Note

MSC highly recommends to set the Prompt to Start Enrollment option to True for elementary schools. Younger children tend to be reluctant about placing their hand on the guide device. With the Prompt to Start Enrollment option is set to false and the nervousness of the younger children, the children have a tendency to slowly place their hand on the device. This results in only a partial capture of the child's palm.

    • Sensor Direction - Chooses the direction of the sensor.
  • Click Ok when you have completed adjusting the settings.

  • Click Ok again to exit out of the Edit Serving Line window.
  • Click Close in the Serving-Line Maintenance window.

Step 8: Exit out of Newton. Then, log back in to Newton for all the device settings to take effect.

Step 9:  Test the palm scanning device.

...

Step 9: Place the student's hand, fingers spread open, all the way to the top of the palm guide so that the middle finger is in between the two finger dividers at the top of the guard. The webbing between the index and middle finger and the middle, right ring-finger should be touching the two finger dividers with the palm flat down. The object is to let as little light in as possible, so the infrared scanner can read the veins.Image Removed   Image Removed

Panel
titleColor#ffffff
titleBGColor#228B22
titleCorrect Hand Placement

Image Added Image Added

Panel
titleColor#ffffff
titleBGColor#FF1919
titleIncorrect Hand Placement

 Image Added Image Added

Image Added Image Added

 

Step 10:

Info

The enrollment process requires two (2) good scans in order to make a positive match.

...